Ex9IR50

The Ex9IR50 DC Rotary Switch Disconnector is an electrical safety device designed for manual disconnection in applications such as photovoltaic (PV) and energy storage systems. In PV systems, this disconnector is employed to manually isolate solar panels for maintenance, installation, or repair tasks. Its utilization category is DC-PV2, which means it is suitable for connecting and disconnecting PV circuits where significant overcurrents may occur. This switch can accommodate bidirectional current flow—useful, for example, in systems where multiple string arrays are connected in parallel to a single inverter, or in configurations involving one or more strings with a battery.

  • Non-polarized, suitable for PV systems
  • Rated current up to 50 A at 1100 V DC
  • Rated current up to 26 A at 1500 V DC
  • Rated voltage up to 1500 V DC
  • Meet requirements of IEC / EN 60947-3
  • From 2 up to 8 layers
  • Utilization category DC-PV2

Ex9A25HU

Air Circuit Breakers from the Ex9A series are engineered for power distribution protection in high-demand settings, including industrial and commercial environments, among others. Tested according to IEC/EN 60947-2 standards, these breakers offer the requisite functionality and reliability for higher-power applications. The Ex9A25-HU variant has been specifically developed to meet the evolving needs of photovoltaic (PV) applications, where the nominal voltage continues to rise. These products are rated for voltages ranging from 800 VAC to 1150 VAC.

  • Air circuit breakers, frame size A25
  • Rated current up to 2500 A
  • Rated operating voltage
  • 800 / 1000 / 1150 V AC
  • Breaking capacity Icu 65 kA
  • Fixed and withdrawable versions
  • Utilization category B acc. to EN 60947-2
  • Compact and modular design
  • Wide range of accessories

Ex9BT3G

Group Change-Over Switches from the Ex9BT3G series are engineered for the switching of auxiliary, control, measuring, and signaling networks. Tested in accordance with the 60947-3 standard, these switches guarantee functional reliability across a broad array of applications. The utilization category AC-22A permits switching operations under load conditions.

  • Meet requirements of IEC EN 60947-3
  • Rated current from 16 A to 40 A
  • Rated operating voltage 240/415 V AC
  • Utilization category AC-22A
  • Contact form ( I-O-II )
  • 1 up to 4-pole versions
  • Rated frequency 50/60 Hz

Ex9EVD

The Ex9EVD is a wall-mounted charger designed for electric vehicles (EVs), intended for household use. This solution comes equipped with a Type B Residual Current Circuit Breaker (RCCB), a necessary safety feature for EV chargers. Given that the EV battery operates on a DC principle, DC current leakage can occur. The built-in Type B RCCB is capable of detecting leakages in both DC and AC currents, as well as pulsating currents at high frequencies.

  • Tested according to IEC/EN 61851-1
  • Including RCCB B type
  • Degree of protection IP 66
  • Installation directly on wall
  • 3-phase versions
  • Adjustable charging current up to 32 A
  • Dynamic Load Balance function (DLB) via external modul orderable separately
  • Plug type 2 (7 pins)

AFDD 6 kA Ex9NLA EL

Voltage-Dependent Arc Fault Detection Circuit-Breakers with Residual Current Operated functionality, Ex9NLA EL, are suitable for both domestic and industrial applications. These circuit-breakers employ an electronic evaluation principle for enhanced accuracy in measuring residual currents. They offer a comprehensive protection suite, including overload, short-circuit, leakage protection, and arc fault detection, all in a compact 3-module width solution.

  • Rated breaking capacity Icn 6 kA
  • Rated residual current 30 mA
  • Rated currents up to 32 A
  • B and C tripping characteristics of installed
    circuit breaker
  • A type of built-in RCD
  • Suitable for applications from -25 to +40°C

Ex9S80

Manual Motor Protective Circuit Breakers, identified by the product number Ex9S80A, offer overload, short-circuit, and phase-failure protection specifically for three-phase asynchronous motors with infrequent start-up cycles. Additionally, these circuit breakers are suitable for power distribution line protection and can also serve as isolators

  • Manual motor protective circuit breakers
  • Meet requirements of IEC/EN 60947-2 and IEC/EN 60947-4-1
  • Rated current Ie up to 80 A at 415 V AC-3
  • Rated operating voltage Ue up to 690V
  • Overload, short-circuit and phase-failure protection
  • Ambient temperature compensation
  • Wide range of accessories